Data Center · 30-60 Minutes Backup Series

CLN480100U

As the global push toward carbon peaking and carbon neutrality intensifies, low-carbon data centers are becoming a key development direction. Compared to traditional lead-acid battery systems, CLN Energy’s Energy Storage Systems (ESS) offer enhanced safety, greater system integration, and more efficient charge/discharge management. Deploying ESS in data centers offers several important benefits: 1. Stabilizing Renewable Energy – ESS can mitigate fluctuations from renewable energy sources, ensuring a stable and continuous power supply for data center operations. 2. Market Participation and Backup Power – ESS can not only serve as a backup energy source but also take part in energy market transactions, generating revenue while supporting reliable operations. 3. UPS Replacement and Grid Interaction – ESS can replace conventional Uninterruptible Power Supplies (UPS), maintaining uninterrupted power flow. Additionally, by interacting with the power grid, it boosts asset efficiency and enhances operational income. CLN Energy’s ESS solutions are well-suited for deployment in data center projects, providing power stability, reliable backup, and scalable capacity to support future growth.

Key specifications

  • Voltage 480V
  • Capacity 100Ah
  • Max. Charge current 50A
  • Max. discharge current200A
CLN Energy CLN480100U

Swipe the table to see all models →

Technical Specification
Product Model CLN240100U CLN384100U CLN480100U
Cell ChemistryLiFePO4
Cell Form FactorPrismatic
Nominal Voltage (Vdc)240384480
Rated Charging Voltage (Vdc)262420525
Nominal Capacity (Ah/kWh)100/24100/38.4100/48
Self-Discharge Rate<3% (0–30 °C / 3 months)
Standard Discharge Current (A)50 (0.5C)50 (0.5C)50 (0.5C)
Maximum Discharge Current (A)200 (2C)200 (2C)200 (2C)
Standard Charging Current (A)25 (0.25C)25 (0.25C)25 (0.25C)
Maximum Charging Current (A)50 (0.5C)50 (0.5C)50 (0.5C)
Cycle Life3000 times @80% DOD, 0.5C/0.5C
Communication InterfaceCAN; RS485; Dry contact
Protection FunctionsOver-temperature, over-current, short circuit, over-charging, over-discharging, etc.
Dimensions (W×D×H) mm600×800×1400600×800×2000600×800×2000
Storage Temperature (°C)0–40
Operating Temperature (°C)15–45 (recommended 20–25)
Relative Humidity5–95%
Altitude (m)≤2000
Cell Specification
Nominal Capacity (Ah)100100100
Nominal Voltage (Vdc)3.23.23.2
Working Voltage Range (Vdc)2.5–3.62.5–3.62.5–3.6
Battery Module Specification
Configuration1P14S1P15S1P15S
Nominal Voltage (Vdc)44.84848
Working Voltage Range (Vdc)39.2–4942–53.542–52.5
Battery Pack Specification
Configuration1P75S1P125S1P150S
Nominal Capacity (Ah)100100100
Nominal Voltage (Vdc)224384480
Working Voltage Range (Vdc)196–245336–420420–525
Weight (kg)310490590
CertificationsUL1642, UN38.3, IEC62619, IEC62133

Built in India

Manufactured at CLN Energy's own plant at Sector 140, Noida — the plant is also the registered office, and the company is listed on the BSE SME platform under scrip 544347. Cells are lithium iron phosphate throughout.

That matters at the two moments location usually does: when something needs looking at, and when a warranty has to be honoured. Packs in service include 22,864 across BSNL's telecom network, backup at RailTel's Pondicherry command control centre, and signalling backup for Southern Railway — each on its own project page with the real configuration.

Standards

  • UN 38.3 Transport
  • IEC 62619 Cell & battery safety
  • IEC 61000 EMC
  • UL 1973 Stationary safety
  • UL 9540A Thermal runaway
  • ISO 9001:2015 Quality

What each standard covers →

Other Data Center models

See the full Data Center range →

Get a quote for the CLN480100U

Tell us the application and the quantity and we will come back with a configuration and a price. For a fleet or a rollout, say how many and we will quote accordingly.

Request a quote Ask on WhatsApp Become a dealer