Residential · Grid Tie Inverter

Grid Tie Inverter CLN-GTI-2000

CLN Energy grid-tie inverter connects solar systems directly to the utility grid (230/400V) without a transformer. Featuring an LCD display and easy controls, it simplifies operation and maintenance, especially in remote areas. With MPPT technology for optimal energy conversion and safety features like anti-islanding protection, it ensures reliable and efficient power management for both residential and commercial systems.

Key specifications

  • Rated AC Output 2 kW
  • Max. PV Input Power 2.6 kW
  • MPPT Voltage Range 70-500 Vdc
  • Certification BIS Certified
CLN Energy Grid Tie Inverter CLN-GTI-2000

Swipe the table to see all models →

Technical Specification
Parameter CLN-GTI-1000 CLN-GTI-1500 CLN-GTI-2000 CLN-GTI-3000 CLN-GTI-4000 CLN-GTI-5000
PV String Input Data
Max. PV Input Power (kW)1.322.63.95.27.5
Max. PV Input Voltage (Vdc)550600
Start-up Voltage (V)80
MPPT Voltage Range (Vdc)70-500
Rated PV Input Voltage (V)360420
Max. Operating PV Input Current (A)20
Max. Input Short Circuit Current (A)30
No. of MPPT Trackers/No. of Strings MPPT Tracker1 / 1
AC Output Side
Rated AC Output Active Power (kW)11.52345
Max. AC Output Apparent Power (kVA)1.11.652.23.34.45.5
Max. AC Output Current (A)5/4.87.5/7.210/9.615/14.420/19.225/24
Rated Output voltage/range (V)220/230V 0.85Un-1.1Un
Grid Connection FormL/N/PE
Rated Output Grid Frequency/Range(Hz)50/45-55, 60/55-65
Power Factor Adjustment Range0.8 Leading to 0.8 Lagging
Total Current Harmonic Distortion THDi<3%
DC Injection Current<0.5% ln
Efficiency
Max. Efficiency97.50%
Euro Efficiency97.00%
MPPT Efficiency>99%
Equipment Protection
DC Polarity Reverse Connection ProtectionYES
Thermal ProtectionYES
Earth Fault DetectionYES
Over voltage Load Drop ProtectionYES
Residual Current (RCD) DetectionYES
Interface
Communication InterfaceRS485/RS232
Monitor ModeGPRS/WIFI/Bluetooth/4G/LAN (optional)
General Data
Operating Temperature Range (°C)(-10 to +60, >45 De-rating)
Permissible Ambient Humidity0-100%
Permissible Altitude (m)4000
Ingress Protection(IP) RatingIP65
Inverter TopologyNon-isolated
Type of CoolingNatural cooling
Grid RegulationIEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-
Richtlinie R25, G99,VDE-AR-N 4105
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
CertificatesBIS Certified

Built in India

Manufactured at CLN Energy's own plant at Sector 140, Noida — the plant is also the registered office, and the company is listed on the BSE SME platform under scrip 544347.

That matters at the two moments location usually does: when something needs looking at, and when a warranty has to be honoured. Packs in service include 22,864 across BSNL's telecom network, backup at RailTel's Pondicherry command control centre, and signalling backup for Southern Railway — each on its own project page with the real configuration.

Standards

  • IEC 61727 Grid connection
  • IEC 62116 Anti-islanding
  • IEC/EN 62109-1/-2 Inverter safety
  • IEC/EN 61000-6 EMC
  • BIS Certified

Other Residential models

See the full Residential range →

Get a quote for the Grid Tie Inverter CLN-GTI-2000

Tell us the application and the quantity and we will come back with a configuration and a price. For a fleet or a rollout, say how many and we will quote accordingly.

Request a quote Ask on WhatsApp Become a dealer